Displaying present location in the site.

NEC Storage M710F

Model Name M710F
Units Unit Types Disk Array Controller
Disk Enclosure (2.5")
Number of Disk Enclosures (Max.) 80
Number of Drive Slots in Total (Max.) *1 960
Number of Drive Slots per Enclosure Disk Enclosure: 24
Host Interface FC (8Gbps/16Gbps): Max 48 ports
FC (32Gbps): Max 24 ports
iSCSI (10Gbps): Max 24 ports
Drive Interface
(Interface between DAC & DE, or between DE's *2)
SAS3.0 (12Gbps)
Cache Memory Capacity 192GB
Backup Method Save to a dedicated area
RAID Level RAID-1, 5, 6, 10, 50, 60
Number of Drives *1 3 to 960
Drive Types SAS SSD 2.5" 200GB,400GB,1.6TB,3.84TB
VRI SAS SSD *3 2.5" 2TB,4TB
RI SAS SSD *3 2.5" 15.3TB
SED SAS SSD *4 2.5" 200GB
Max. Storage Capacity *5 SAS SSD 2651.7TiB
VRI SAS SSD *3 2729.8TiB
RI SAS SSD *3 8744.7TiB
SED SAS SSD *4 132.4TiB
Chassis Dimensions (Width x Depth x Height) Disk Array Controller (Rack Unit) 482.6 x 633.8 x 175.4 mm (4U, w/o Front Bezel)
482.6 x 643.8 x 175.4 mm (4U, w/ Front Bezel) *6
Disk Enclosure (Rack Unit) 482.6 x 548.5 x 87.4 mm (2U, w/o Front Bezel)
482.6 x 558.5 x 87.4 mm (2U, w/ Front Bezel) *6
Weight Disk Array Controller 48kg or less
Disk Enclosure 25kg or less
Power Voltage, Frequency, Phase AC100 - 240V, 50/60Hz, Single phase
Power Consumption(Max. / @25 deg.C) Disk Array Controller *7 1,190W(1,200VA) / 1,065W
Disk Enclosure 370W(375VA) / 305W
Temperature Operating: 5 to 40 degrees Celsius
Non-operating: -10 to 60 degrees Celsius
Relative Humidity Operating: 10 to 80%RH
Non-operating: 5 to 80%RH
Support OS *8 FC: Windows, Linux, VMware, HP-UX, AIX, Solaris
iSCSI: Windows, Linux, VMware
  • *
    1: Host ports and drive slots are added exclusively.
  • *
    2: DAC stands for Disk Array Controller, DE stands for Disk Enclosure.
  • *
    3: VRI stands for Very Read Intensive. RI stands for Read Intensive.
  • *
    4: SED stands for Self-Encrypting Drive.
  • *
    5: TiB represents 1,024^4B.
  • *
    6: The Front Bezel is sold separately.
  • *
    7: Host interface is FC.
  • *
    8: Please contact NEC for possible restrictions.