Displaying present location in the site.

NEC Storage M710

Model Name M710
Units Unit Types Disk Array Controller
Disk Enclosure (2.5" & 3.5")
Number of Disk Enclosures (Max.) 80
Number of Drive Slots in Total (Max.) *1 960
Number of Drive Slots per Enclosure Disk Enclosure (2.5"): 24
Disk Enclosure (3.5"): 12
Host Interface FC (8Gbps/16Gbps): Max 48 ports
FC (32Gbps): Max 24 ports
iSCSI (10Gbps): Max 24 ports
Drive Interface
(Interface between DAC & DE, or between DE's *2)
SAS3.0 (12Gbps)
Cache Memory Capacity 96GB or 192GB
Backup Method Save to a dedicated area
RAID Level *3,*4 RAID-0, 1, 5, 6, 10, 50, 60, TM
Number of Drives *1 3 to 960
Drive Types SAS HDD 2.5": 600GB,1.2TB,1.8TB,2.4TB(10,000rpm) / 300GB,600GB(15,000rpm)
3.5": 300GB(15,000rpm)
Nearline SAS HDD 2.5": 1TB,2TB(7,200rpm)
3.5": 2TB,4TB,6TB,8TB,10TB,12TB(7,200rpm)
SAS SSD 2.5": 200GB,400GB,1.6TB,3.84TB
3.5": 200GB,400GB,1.6TB,3.84TB
VRI SAS SSD *5 2.5": 2TB,4TB
3.5": 2TB,4TB
RI SAS SSD *5 2.5": 15.3TB
SED SAS HDD *6 2.5": 600GB(10,000rpm) / 600GB(15,000rpm)
SED Nearline SAS HDD *6 3.5": 4TB(7,200rpm)
SED SAS SSD *6 2.5": 200GB
3.5": 200GB
Max. Storage Capacity *7 SAS HDD 2.5": 1812.9TiB
3.5": 221.2TiB
Nearline SAS HDD 2.5": 1517.1TiB
3.5": 9099.6TiB
SAS SSD 2.5": 2651.7TiB
3.5": 2651.7TiB
VRI SAS SSD *5 2.5": 2729.8TiB
3.5": 2729.8TiB
RI SAS SSD *5 2.5": 8744.7TiB
SED SAS HDD *6 2.5": 445.1TiB
SED Nearline SAS HDD *6 3.5": 3033.0TiB
SED SAS SSD *6 2.5": 132.4TiB
3.5": 132.4TiB
Chassis Dimensions (Width x Depth x Height) Disk Array Controller (Rack Unit) 482.6 x 633.8 x 175.4 mm (4U, w/o Front Bezel)
482.6 x 643.8 x 175.4 mm (4U, w/ Front Bezel) *8
Disk Enclosure (Rack Unit) 482.6 x 548.5 x 87.4 mm (2U, w/o Front Bezel)
482.6 x 558.5 x 87.4 mm (2U, w/ Front Bezel) *8
Weight Disk Array Controller 48kg or less
Disk Enclosure 2.5" 26kg or less
3.5" 29kg or less
Power Voltage, Frequency, Phase AC100 - 240V, 50/60Hz, Single phase
Power Consumption(Max. / @25 deg.C) Disk Array Controller *9 1,190W(1,200VA) / 1,065W
Disk Enclosure 350W(350VA) / 285W (SAS HDD)
315W(320VA) / 250W (Nearline SAS HDD)
Temperature Operating: 5 to 40 degrees Celsius
Non-operating: -10 to 60 degrees Celsius
Relative Humidity Operating: 10 to 80%RH
Non-operating: 5 to 80%RH
Supported OS *10 FC: Windows, Linux, VMware, HP-UX, AIX, Solaris
iSCSI: Windows, Linux, VMware
  • *
    1: Host ports and drive slots are added exclusively.
  • *
    2: DAC stands for Disk Array Controller, DE stands for Disk Enclosure.
  • *
    3: It is not recommended to use RAID-0, which has a risk of data loss in case of one drive error.
  • *
    4: The RAID levels available for SSD are RAID-1, 5, 6, 10, 50, and 60.
  • *
    5: VRI stands for Very Read Intensive. RI stands for Read Intensive.
  • *
    6: SED stands for Self-Encrypting Drive.
  • *
    7: TiB represents 1,024^4B.
  • *
    8: The Front Bezel is sold separately.
  • *
    9: Host interface is FC.
  • *
    10: Please contact NEC for possible restrictions.