NEC Storage M320
Model Name | M320 | ||
---|---|---|---|
Units | Unit Types | Disk Array Controller (2.5" & 3.5") Disk Enclosure (2.5" & 3.5") | |
Number of Disk Enclosures (max.) | 2.5": 27 3.5": 39 | ||
Number of Drive Slots per Enclosure | Disk Array Controller (2.5"): 24 Disk Array Controller (3.5"): 12 Disk Enclosure (2.5"): 24 Disk Enclosure (3.5"): 12 | ||
Host Interface | 16G FC: 24 ports (max.), 32G FC: 16 ports (max.) 10G/25G iSCSI optical 16 ports (max.), 1G/10G iSCSI copper 16 ports(max.) SAS (12Gbps): 8 ports (max.) | ||
Drive Interface | SAS3.0 (12Gbps) | ||
Cache Memory | Capacity | 96GB / 192GB / 384GB | |
Backup Method | Save to a dedicated area | ||
RAID Level *1 | RAID-0, 1, 5, 6, 10, 50, 60, TM | ||
Number of Drives | 3 to 672 | ||
Drive Types | SAS HDD | 2.5": 600GB, 1.2TB, 1.8TB, 2.4TB (10,000rpm) 300GB, 600GB (15,000rpm) | |
Nearline SAS HDD | 3.5": 4TB, 8TB, 12TB (7,200rpm) | ||
SAS SSD | 2.5": 400GB, 1.6TB, 3.2TB 3.5": 400GB, 1.6TB, 3.2TB | ||
RI SAS SSD *2 | 2.5": 3.84TB, 7.68TB, 15.3TB 3.5": 3.84TB, 7.68TB, 15.3TB | ||
SED SAS HDD *3 | 2.5": 600GB(10,000rpm) / 600GB(15,000rpm) | ||
SED Nearline SAS HDD *3 | 3.5": 4TB(7,200rpm) | ||
SED SAS SSD *3 | 2.5": 400GB, 3.2TB 3.5": 400GB, 3.2TB | ||
Storage Capacity (max.) *4 | SAS HDD | 2.5": 1269.0TiB | |
Nearline SAS HDD | 3.5": 4549.8TiB | ||
SAS SSD | 2.5": 1652.3TiB 3.5": 1180.2TiB | ||
RI SAS SSD *2 | 2.5": 8161.8TiB 3.5": 5829.8TiB | ||
SED SAS HDD *3 | 2.5": 311.6TiB | ||
SED Nearline SAS HDD *3 | 3.5": 1516.5TiB | ||
SED SAS SSD *3 | 2.5": 1652.2TiB 3.5": 1180.2TiB | ||
Chassis Dimensions (Width x Depth x Height) | Disk Array Controller (Rack Unit) | 482 x 568 x 88 mm (2U, w/o Front Bezel) 483 x 606 x 88 mm (2U, w/ Front Bezel) *5 | |
Disk Enclosure (Rack Unit) | 482 x 517 x 88 mm (2U, w/o Front Bezel) 483 x 555 x 88 mm (2U, w/ Front Bezel) *5 | ||
Weight | Disk Array Controller | 2.5": 30kg or less 3.5": 32kg or less | |
Disk Enclosure | 2.5": 26kg or less 3.5": 28kg or less | ||
Power Voltage, Frequency, Phase | AC100 - 240V, 50/60Hz, Single phase | ||
Power Consumption(max. @25 deg.C) | Disk Array Controller *6 | 725W / 735VA (SAS HDD) 680W / 685VA (Nearline SAS HDD) 830W / 840VA (SSD) | |
Disk Enclosure | 325W / 330VA (SAS HDD) 285W / 290VA (Nearline SAS HDD) 425W / 430VA (SSD) | ||
Temperature | Operating: 5 to 40 degrees Celsius Non-operating: -10 to 60 degrees Celsius | ||
Relative Humidity | Operating: 10 to 80%RH Non-operating: 5 to 80%RH | ||
Supported OS *7 | FC: Windows, Linux, VMware, HP-UX, AIX, Solaris iSCSI, SAS host interface: Windows, Linux, VMware |
- *
- *1: It is not recommended to use RAID-0, which has a risk of data loss in case of one drive error.
- *2: RI stands for Read Intensive.
- *3: SED stands for Self-Encrypting Drive.
- *4: TiB represents 1,024^4B.
- *5: The Front Bezel is sold separately.
- *6: Host interface is Fibre Channel.
- *7: Please contact NEC for possible restrictions.