Oct 10, 2006
Express5800/Backup Devices
Distribution SUSE Linux Enterprise Server 10 for EM64T
Meanings of letters
A ---Function without external drivers
B ---Function with external drivers
C ---Not function
D ---Not Supported

Backup Devices UP

-Hardware configuration

Connection Code Model/Device Driver
Conn1 N8103-75 Additional SCSI Controller (PCI-X, U320) aic79xx
Conn2 N8103-95 Additional SCSI Controller (Ultra160) aic7xxx
Conn3 (USB Connecter) USB controller -

-Evaluation

Code Model/Device Result Comment
N8141-28B Device Expansion Unit A Put in Tape Devices.
N8160-71 External tape box A
N8151-45(F) Built-in DAT (DDS1/2/3/4, 20GB) A tar,mt
N8151-51A Built-in DAT (DDS3/4/DAT72, 36GB) A
N8151-59 Built-in LTO (LTO2, 200GB) A
N8151-60A Additional AIT (IDE,AIT1 Turbo, 40GB) -
N8151-61A Additional AIT (IDE,AIT2 Turbo, 80GB) -
N8151-65 Built-in AIT (AIT-3Ex, 150GB)  
N8560-22 External DAT(DDS1/2/3/4, 20GB)  
N8151-29 Built-in auto-loader unit   tar,mt,mtx
(*1)
N8151-39 Built-in auto-loader unit (DDS1/2/3/4,20GB×8) A
N8151-55A Built-in AIT (AIT-1 Turbo, 40GB) A
N8151-68 Built-in auto-loader unit (AIT3Ex, 150GB×16) A
N8160-67 External AIT auto-loader unit
(AIT3Ex, for rack mount (1U) 150GB×8)
A
N8160-70 External AIT auto-loader unit (AIT-2Turbo, 80GBx8)  
N8160-73 External DAT (DAT72, 36GB USB) A tar,mt

(*1)
In case the system cannot probe multi luns, do as follows.
  1. Check your kernel version.
    ex) uname -r
  2. Add 'options scsi_mod max_luns=2' to /etc/modprobe.conf.
  3. Make initrd image. Care the kernel version you have got.
    ex) mkinitrd -f /boot/initrd-2.6.9-34.ELsmp.img 2.6.9-34.ELsmp
  4. Restart the Operation System.
go back UP