Jan 24, 2008
Express5800/120Li
Distribution Red Hat Enterprise Linux 5.1 (x86/x86_64)
( KERNEL 2.6.18-53.el5 )
Meanings of letters
A ---Function without third party drivers
B ---Function with third party drivers
C ---Not function
D ---Not Supported
OS Installation / Xen Virtualization / Basic operation / Hardware addition / LAN Adapters / Backup Devices

Model UP

Code Model

N8100-1294
N8100-1295
N8100-1297
N8100-1298
Express5800/120Li ( diskless model)
DualCore Intel® Xeon®Processor 5110 (1.60 GHz)
DualCore Intel® Xeon®Processor 5130 (2 GHz)
DualCore Intel® Xeon®Processor 5160 (3 GHz)
QuadCore Intel® Xeon®Processor E5345 (2.33 GHz)
* You must update BIOS if the version is less than 1.0.5M49. See HERE.
* You must update BMC firmware if the version is less than 00.51. See HERE No. .

OS Installation UP

-Hardware configuration

Configuration Drive Outline qty
1 SAS Additional HDD 3
2 SAS-DAC N8103-91 Disk Array Controller (for internal SAS HDDs) 1
Additional HDD (RAID5) 3
3 SAS-ZCR N8103-99 Disk Array Controller (for SAS HDDs 0ch) 1
Additional HDD (RAID5) 3
* Conf3: In case the firmware version of N8103-99 Disk Array Controller is 2.02.00-0095 or 1.03.01-0178, you must get new one from here to update.
* You must choose the same type of HDDs for a RAID drive.
* LSI Logic Embedded MegaRAID is not available on this Linux.

-Evaluation

Checklist Result Comment
Conf1 Conf2 Conf3
OS installation A A A Boot from CD-ROM.
Making partitions 14 14 14 Using the whole drive
Hard Drives A A A Copy and compare data files.
Availability of Degraded RAID
( Hotplug.)
- A A Remove one HDD from the running system.
Rebuild of Degraded RAID
( Hotplug.)
- A A Rebuilding automatically.
I/O access running 12h 12h 12h I/O access running
Reboot 10 10 10 Number of repeated system rebooting.
I/O performance       (MB/sec) hdparm -t /dev/sda command

Xen Virtualization UP

Checklist Result Comment
Creating Virtual Machines (full-virtualized) -
(*1)
the number of created Virtual Machines.
Creating Virtual Machines (para-virtualized) 4 the number of created Virtual Machines.
Drives on Virtual Machines A Copy and compare data files.
Networking on Virtual Machines A ssh,ftp
I/O access running(full-virtualization) -
(*1)
I/O access running
I/O access running(para-virtualization) 12h I/O access running
Reboot (dom0) 10 Number of repeated system rebooting.
Reboot (domU) 10
(*2)
Number of repeated system rebooting.
(*1)
Full-virtualization is not recommended.

(*2)
Booting of Guest domain is sometimes canceled for unknown reasons.

Basic operation UP

Checklist Result Comment
X Window System A 1024x768, thousands colors.
PS/2 Mouse/keyboard A
(*1)
Test on X Window System.
Built-in LAN ports B
(*2)
ssh, ftp
Built-in LAN ports Teaming (bonding) A
(*3)
Use bonding driver. See the kernel document for information about bonding.
CPU information A cat /proc/cpuinfo
Memory information A cat /proc/meminfo
Maximum CPUs 2 Number of physical CPUs.
Maximum Memory 48
(*4)
Size of Main Memory. (GB)
DVD-ROM Drive A Copy and compare data files.
Floppy Drive A
Serial port A Configure to login.
(*1)
To fix Keyboard problem, BMC firmware must be updated.

(*2)
Is is recommended to update ethernet driver to fix some problems. See Intel® website and get newest e1000 driver.

(*3)
Bonding does not function on Xen kernel.

(*4)
On RHEL5 x86 system, less than 16GB memory is supported. PAE kernel is available in case memory amount is from 4GB to 16GB. On RHEL5 x86_64 system, memory amount is not limited.

Hardware Addition UP

Code Model/Device Result Comment
N8101-346 Additional CPU (Xeon(1.60G)) A cat /proc/cpuinfo
N8101-361 Additional CPU (Xeon(2G)) A
N8101-347 Additional CPU (Xeon(3G)) A
N8101-363 Additional CPU (Xeon(2.33G)) A
N8102-269 1GB Additional Memory board(512MB x2) A cat /proc/meminfo
N8102-270 2GB Additional Memory board(1GB x2) A
N8102-271 4GB Additional Memory board(2GB x2) A
N8102-272 8GB Additional Memory board(4GB x2) A
N8150-199 Additional 36.3GB HDD (SAS,15000rpm) A Copy and compare data files.
N8150-200 Additional 73.2GB HDD (SAS,15000rpm) A
N8150-201 Additional 146.5GB HDD(SAS,15000rpm) A
N8150-226 Additional 300GB HDD (SAS,15000rpm) A
N8151-72A Built-in FDD (USB) A Copy and compare data files.
N8160-74 External FDD (USB) A Connected after OS boot, Copy and compare data files.

LAN Adapters UP
See ( HERE ), Option Devices page.

Backup Devices UP
See ( HERE ), Option Devices page.

-Hardware configuration

Connection Code Model/Device Driver Version
Conn1 N8103-95 Additional SCSI Controller (U160) aic7xxx 7.0
Conn2 N8103-75 Additional SCSI Controller (U320) aic79xx 3.0
Conn3 - USB controller (USB2.0) - -

-Evaluation

Checklist Result Comment
Conn1 Conn2 Conn3
Backup, Restore A A A tar command
Reboot 5 5 5 Number of repeated system rebooting.

go back UP