Please note that JavaScript and style sheet are used in this website,
Due to unadaptability of the style sheet with the browser used in your computer, pages may not look as original.
Even in such a case, however, the contents can be used safely.

| INPUT | REMOTE CONTROL | |||
| ETI Input | 2 x ETI ,2048kbps, 75ΩBNC | |
Remote | Parallel: status/alarm/command; Ribbon type receptacle, 36-pin |
| Reference | 10MHz, 0dBm ±3dB, 50Ω BNC (N/A when internal GPS receiver exists) |
Ethernet | TCP/IP, 10/100BASE-T, RJ-45 UDP/IP for SNMP |
|
| 1pps Input (GPS ANT Input) |
1Hz, TTL level, 50Ω BNC ( when optional internal GPS receiver is employed, this input is used for GPS ANT input, 50Ω TNC-female) |
|||
| OUTPUT | Other | |||
| RF OUT | Band ||| , 170-240MHz 50Ω N female (PA) : 330W 50Ω 1-5/8” EIA-UF (Combiner) : 650W to 2.6kW 50Ω 1-5/8” EIA-UF: with Rack option (without output BPF) IMP <= -36dB Exciter output: +10dBm, 50Ω BNC Frequency stability: <= ±1x10-7day@+25℃ (without external reference) |
|
Power Supply | 380/400/415V, 3 phases, 4 wires as standard,Also possible to operate with single phase, 220/230/240V or 200/208/220/230V, 3 phases, 3 wires as standard. |
| Voltage Fluctuation | ±15 % | |||
| Power Supply Frequency | 50/60Hz ±5 % | |||
| RF Monitor | More than 0dBm, 50Ω BNC | Ambient Temperature | 0° to +45° | |
| Local Monitor | Center frequency of RF output, 0dBm, CW, 50Ω BNC | Relative Humidity | <= 90% | |
| OUTPUT | Size WxDxH (mm) | Weight (kg) | |
| Exciter | DS-1000 | 480 ×520 × 44 (1U) | 6.5 |
| TX CONTROL | HPC-1427 | 480 ×572 × 44 (1U) | 4.8 |
| PA | VS370RE | 480 ×500 × 170 (4U) | 21 |
Datasheet