Please note that JavaScript and style sheet are used in this website,
Due to unadaptability of the style sheet with the browser used in your computer, pages may not look as original.
Even in such a case, however, the contents can be used safely.

ShieldPRO N22G - Environmental Conditions -

Environmental Conditions *1 *4

  Items  Conditions
  Standard Hard disk and Standard Battery, Standard HDD, Long lasting Battery, Silicon Disk and Standard Battery

  Wide Temperature Hard disk / Wide Temperature Battery, Silicon Disk / Wide Temperature Battery

  Temperature  During operation*2  Note   5 to 45 degrees C   -20 to 50 degrees C
  Tablet   5 to 40 degrees C   -20 to 45 degrees C
  Non-operation   -40 to 70 degrees C
  Assessment 
   criteria
  IEC 60068-2-1,2,14/MIL-STD-810G,                    
  Method  501.5   502.5
 Humidity  During operation   5% to 95% RH (no condensation)
  Non-operation   5% to 95% RH (no condensation)
  Assessment 
  criteria
  IEC 60068-2-30/MIL-STD-810G,
  Method 507.5
  Altitude  During operation   15,000ft (4,572m)
  Non-operation   40,000ft (12,190m)
  Rate of change   2,000 ft/min(609.6m/min)
  Assessment
  criteria
  IEC 60068-2-13/MIL-STD-810G, Method 500.5
  Shock 
 Resistance
                 *3
  During operation   147m/S²
  Non-operation   490m/S²
  Assessment 
  criteria
  IEC60068-2-67/MIL-STD-810G, Method 516.6
  Vibration
  Resistance
                  *3
  During operation

  [Sine wave]      
  Frequency 10~55Hz:0.075mm (0-P) 
  Frequency 55Hz~500Hz:9.8m/S²

  Non-operation

[ Sine wave]
  Frequency 10~55Hz:0.15mm (0-P)
  Frequency 55Hz~500Hz:19.6m/S²[ Random wave]
  Frequency 20Hz~1000Hz:0.04GS²  Frequency 1000Hz~2000Hz:-6dB/Octave

  Assessment criteria  During operation

[ Sine wave excitation ]
IEC 60068-2-6

  Non-operation

[ Sine wave excitation ]
IEC 60068-2-6
[ Random wave oscillation]
MIL-STD-810F,Method 514.5 Category 24 FIGURE 514.5C-17

*1   In case ShieldPRO operate continuously for a long time, even under the environment described in this conditions, it may not operate rightly. In addition, in case of using 3rd party components, ShieldPRO will be subject to the environment conditions of the component. If ShieldPRO is kept under the temperature at the range below 0 degree and/or over 50 degrees, it may be possible that the clock of ShieldPRO will be fast or slow. In such case please set the clock again.

*2   The battery of ShieldPRO can be charged under the temperature at the range from 5 to 40 degrees C with non-operational mode.

*3   This does not guarantee the durability for sympathetic vibrations occurring at close to the natural frequency of the ShieldPRO. 

*4  This environmental conditions are for ShieldPRO main unit. The environmental conditions for peripherals are different from it.