| Express5800/R120a-1 | |
| Distribution | CentOS 5.4 (x86/x86_64) ( KERNEL 2.6.18-164.el5 ) |
| Meanings of letters |
| A ---Function without third party drivers B ---Function with third party drivers C ---Not function D ---Not supported blank---Not tested |
| OS Installation / Xen Virtualization / Basic operation / Hardware addition / Backup Devices |
| Model | UP |
| Code | Model |
|---|---|
N8100-1511 N8100-1512 N8100-1513 N8100-1514 N8100-1515 |
R120a-1 2.5inch disk model ( diskless model) DualCore Intel®Xeon®Processor E5502 1.86 GHz QuadCore Intel®Xeon®Processor E5504 2 GHz QuadCore Intel®Xeon®Processor E5520 2.26 GHz QuadCore Intel®Xeon®Processor X5550 2.66 GHz QuadCore Intel®Xeon®Processor X5570 2.93 GHz |
N8100-1516 N8100-1517 N8100-1518 N8100-1519 N8100-1520 |
R120a-1 3.5inch disk model ( diskless model) DualCore Intel®Xeon®Processor E5502 1.86 GHz QuadCore Intel®Xeon®Processor E5504 2 GHz QuadCore Intel®Xeon®Processor E5520 2.26 GHz QuadCore Intel®Xeon®Processor X5550 2.66 GHz QuadCore Intel®Xeon®Processor X5570 2.93 GHz |
| OS Installation | UP |
-Hardware configuration
| Configuration | Drive | Outline | qty |
|---|---|---|---|
| 1 | 2.5inch disk model SAS-DAC RAID1 |
Built-in Disk Array Controller (for internal SATA/SAS HDDs) ( or N8103-118 ) |
1 |
| Additional HDD (RAID1) | 2 | ||
| 2 | 3.5inch disk model SATA/SAS-DAC RAID1 |
N8103-116A/N8103-118A Disk Array Controller (for internal SATA/SAS HDDs) | 1 |
| Additional HDD (RAID1) | 2 | ||
| 3 | 2.5inch disk model SAS-DAC RAID5 |
Built-in Disk Array Controller (for internal SATA/SAS HDDs) N8103-119 RAID upgrade kit ( or N8103-118 ) |
1 |
| Additional HDD (RAID5) | 3 | ||
| 4 | 3.5inch disk model SATA/SAS-DAC RAID5 |
N8103-117A/N8103-118A Disk Array Controller (for internal SATA/SAS HDDs) | 1 |
| Additional HDD (RAID5) | 3 | ||
| 5 | 2.5inch disk model SAS-DAC RAID6 |
Built-in Disk Array Controller (for internal SATA/SAS HDDs) N8103-119 RAID upgrade kit ( or N8103-118 ) |
1 |
| Additional HDD (RAID6) | 4 | ||
| 6 | 3.5inch disk model SATA |
Additional HDD | 3 |
| Checklist | Result | Comment | |||
|---|---|---|---|---|---|
| Conf1,2 | Conf3,4 | Conf5 | Conf6 | ||
| OS installation | A (*1,2) |
A (*1,2) |
A (*1,2) |
A (*1,2) |
Boot from distribution's CD/DVD media. |
| Making partitions | 14 | 14 | 14 | 14 | Using the whole drive |
| Hard Drives | A | A | A | A | Copy and compare data files. |
| Availability of Degraded RAID | A | A | A | D | Remove one HDD from the running system on Hotplug type. |
| Rebuild of Degraded RAID | A | A | A | D | Rebuild automatically on Hotplug type. |
| I/O access running | 12h | 12h | 12h | 12h | I/O access running |
| Reboot | 10 | 10 | 10 | 10 | The number of times. |
(*1)
On x86 system, when 'boot:' is displayed at the beginning of installation, type and enter following strings.
linux apic=bigsmp
(*2)NECESSARY
Disable EDAC modules. EDAC module will prevent hardware from collecting IPMI logs which is necessary for hardware support.
- Add following sentences to /etc/modprobe.conf.
install *_edac /bin/true
install edac_* /bin/true
- Restart the Operation System.
- Check that string "edac" is not shown in the result of lsmod.
| Xen Virtualization | UP |
| Checklist | Result | Comment |
|---|---|---|
| Creating Virtual Machines (full-virtualized) | (*1) | Number of created Virtual Machines. |
| Creating Virtual Machines (para-virtualized) | 2 | Number of created Virtual Machines. |
| Drives on Virtual Machines | A | Copy and compare data files. |
| Networking on Virtual Machines | A | ssh,ftp |
| I/O access running(full-virtualization) | (*1) | I/O access running |
| I/O access running(para-virtualization) | 12h | I/O access running |
| Reboot (dom0) | 10 | The number of times. |
| Reboot (domU) | 10 | The number of times. |
(*1)
Please note that the Full-virtualization is high load.
| Basic operation | UP |
| Checklist | Result | Comment |
|---|---|---|
| X Window System | A | 1024x768, thousands colors. |
| PS/2 Mouse/keyboard | A | Test on X Window System. |
| Built-in LAN ports | A | ssh and ftp |
| Built-in LAN ports Teaming (bonding) | A (*1) |
Use bonding driver. See the kernel document about bonding. |
| CPU information | A | cat /proc/cpuinfo |
| Memory information | A | cat /proc/meminfo |
| Maximum CPUs | 2 | Number of physical CPUs. |
| Maximum Memory | 96 (*2) |
Size of Main Memory. (GB) |
| Optical disk drive | A | Copy and compare data files. |
| Floppy drive | A | |
| Serial port | A | Configure to login. |
(*1)
Bonding does not function on Xen kernel.
(*2)
On x86 system, PAE kernel is available in case memory amount is from 4GB to 16GB.
On x86 system, less than 16GB memory is supported.
| Hardware Addition | UP |
| Model/Device | Result | |
|---|---|---|
| Hard drive (HDD) | 2.5inch SAS | A |
| 3.5inch SAS | A | |
| 3.5inch SATA | A | |
| Backup devices | (*1) | |
| LAN Adapters | (*1) | |
(*1)
See ( HERE ), Option Devices page.
| Backup Devices | UP |
-Hardware configuration
| Connection | Code | Model/Device | Driver |
|---|---|---|---|
| Conn1 | N8103-95 | Additional SCSI Controller (U160) | aic7xxx |
| Conn2 | N8103-75 | Additional SCSI Controller (U320) | aic79xx |
| Conn3 | N8103-107 | Additional SCSI Controller (U320) | aic79xx |
| Conn4 | - | USB controller (USB2.0) | - |
| Conn5 | N8103-104A | Additional SAS Controller (PCIe x8) | mptxxx |
| Checklist | Result | Comment | ||||
|---|---|---|---|---|---|---|
| Conn1 | Conn2 | Conn3 | Conn4 | Conn5 | ||
| Backup, Restore | A | A | A | A | A | tar command |
| Reboot | 5 | 5 | 5 | 5 | 5 | The number of times. |
| go back | UP |