Dec. 8, 2009
Express5800/iR120a-1E
Distribution CentOS 5.4 (x86/x86_64)
( KERNEL 2.6.18-164.el5 )
Meanings of letters
A ---Function without third party drivers
B ---Function with third party drivers
C ---Not function
D ---Not supported
blank---Not tested
OS Installation / Xen Virtualization / Basic operation / Hardware addition / Backup Devices

Model UP

Code Model

N8100-1575Y
N8100-1576Y
N8100-1577Y
Express5800/iR120a-1E 2.5inch disk model ( diskless model)
QuadCore Intel®Xeon®Processor E5504 2 GHz
QuadCore Intel®Xeon®Processor L5520 2.26 GHz
QuadCore Intel®Xeon®Processor L5506 2.13 GHz

N8100-1578Y
N8100-1579Y
N8100-1580Y
Express5800/iR120a-1E 3.5inch disk model ( diskless model)
QuadCore Intel®Xeon®Processor E5504 2 GHz
QuadCore Intel®Xeon®Processor L5520 2.26 GHz
QuadCore Intel®Xeon®Processor L5506 2.13 GHz

OS Installation UP

-Hardware configuration

Configuration Drive Outline qty
1 2.5inch disk model
SATA/SSD
Additional HDD 6
2 3.5inch disk model
SATA
Additional HDD 4
3 2.5inch disk model
SATA/SSD/SAS-DAC
RAID1
N8103-116A/N8103-118A Disk Array Controller (for internal SATA/SAS HDDs) 1
Additional HDD (RAID1) 2
4 3.5inch disk model
SATA-DAC
RAID1
N8103-116A/N8103-118A Disk Array Controller (for internal SATA/SAS HDDs) 1
Additional HDD (RAID1) 2
5 2.5inch disk model
SATA/SSD/SAS-DAC
RAID5
N8103-117A/N8103-118A Disk Array Controller (for internal SATA/SAS HDDs) 1
Additional HDD (RAID5) 3
6 3.5inch disk model
SATA-DAC
RAID5
N8103-117A/N8103-118A Disk Array Controller (for internal SATA/SAS HDDs) 1
Additional HDD (RAID5) 3
7 2.5inch disk model
SATA/SSD/SAS-DAC
RAID6
N8103-117A/N8103-118A Disk Array Controller (for internal SATA/SAS HDDs) 1
Additional HDD (RAID6) 4
8 3.5inch disk model
SATA-DAC
RAID6
N8103-117A/N8103-118A Disk Array Controller (for internal SATA/SAS HDDs) 1
Additional HDD (RAID6) 4

-Evaluation

Checklist Result Comment
Conf1,2 Conf3,4,5,6,7,8
OS installation A
(*1,2)
A
(*1,2)
Boot from distribution's CD/DVD media.
Making partitions 14 14 Using the whole drive
Hard Drives A A Copy and compare data files.
Availability of Degraded RAID D A Remove one HDD from the running system on Hotplug type.
Rebuild of Degraded RAID D A Rebuild automatically on Hotplug type.
I/O access running 12h 12h I/O access running
Reboot 10 10 The number of times.
(*1)
If it is x86 system, do the following steps.
Boot from Installation CD/DVD media and 'boot:' is displayed, type and enter following strings.
linux apic=bigsmp

(*2)NECESSARY
Disable EDAC modules. EDAC module will prevent hardware from collecting IPMI logs which is necessary for hardware support.
  1. Add following sentences to /etc/modprobe.conf.
    install *_edac /bin/true
    install edac_* /bin/true
  2. Restart the Operation System.
  3. Check that string "edac" is not shown in the result of lsmod.

Xen Virtualization UP

Checklist Result Comment
Creating Virtual Machines (full-virtualized) -
(*1)
Number of created Virtual Machines.
Creating Virtual Machines (para-virtualized) 2 Number of created Virtual Machines.
Drives on Virtual Machines A Copy and compare data files.
Networking on Virtual Machines A ssh,ftp
I/O access running(full-virtualization) -
(*1)
I/O access running
I/O access running(para-virtualization) 12h I/O access running
Reboot (dom0) 10 The number of times.
Reboot (domU) 10 The number of times.
(*1)
Full-virtualization is not recommended.

Basic operation UP

Checklist Result Comment
X Window System A 1024x768, thousands colors.
Mouse/keyboard A Test on X Window System.
Built-in LAN ports A ssh and ftp
Built-in LAN ports Teaming (bonding) A
(*1)
Use bonding driver. See the kernel document for information about bonding.
CPU information A cat /proc/cpuinfo
Memory information A cat /proc/meminfo
Maximum CPUs 2 Number of physical CPUs.
Maximum Memory 32
(*2)
Size of Main Memory. (GB)
Optical disk drive A Copy and compare data files.
Floppy drive A
Serial port A Configure to login.
(*1)
Bonding does not function on Xen kernel.

(*2)
On x86 system, PAE kernel is available in case memory amount is from 4GB to 16GB.
On x86 system, the memory of less than 16GB memory is confirmed.

Hardware Addition UP

Model/Device Result
Hard drive (HDD) 2.5inch SAS A
2.5inch SATA A
2.5inch SSD A
3.5inch SATA A
Backup devices (*1)
LAN Adapters (*1)
(*1)
See ( HERE ), Option Devices page.

Backup Devices UP

-Hardware configuration

Connection Code Model/Device Driver
Conn1 N8103-107 Additional SCSI Controller (U320) aic79xx
Conn2 - USB controller (USB2.0) -

-Evaluation

Checklist Result Comment
Conn1 Conn2
Backup, Restore A A tar command
Reboot 5 5 The number of times.

go back UP