| Express5800/GT110d-S | |
| Distribution | Red Hat Enterprise Linux 6.1 (x86_64) ( KERNEL 2.6.32-131.0.15.el6 ) |
| Meanings of letters |
| A ---Function without third party drivers B ---Function with third party drivers C ---Not function D ---Not supported blank---Not tested |
| OS Installation / Basic operation / Hardware addition / Backup Devices |
| Model | UP |
| Code | Model |
|---|---|
N8100-1769Y N8100-1770Y |
Express5800/GT110d-S 3.5inch HDD model (Air-cooled model) Intel®Pentium® G620 (2.60GHz, 2C/2T) Intel®Xeopn® E3-1220 (3.10GHz 2C/4T) |
N8100-1771Y N8100-1772Y |
Express5800/GT110d-S 2.5inch HDD model (Air-cooled model) Intel®Pentium® G620 (2.60GHz, 2C/2T) Intel®Xeopn® E3-1220 (3.10GHz 2C/4T) |
N8100-1773Y |
Express5800/GT110d-S 3.5inch HDD model (Water-cooled model) Intel®Core® i3-2120 (3.30GHz, 2C/4T) |
N8100-1774Y |
Express5800/GT110d-S 2.5inch HDD model (Water-cooled model) Intel®Core® i3-2120 (3.30GHz, 2C/4T) |
| OS Installation | UP |
-Hardware configuration
| Configuration | Drive | Outline |
|---|---|---|
| 1 | 3.5inch SATA 2.5inch SATA/SAS LSI RAID |
N8103-129 RAID Controller(256MB, RAID0/1/10) Additional HDD |
| 2 | 3.5inch SATA 2.5inch SATA/SAS LSI RAID |
N8103-130 RAID Controller(256MB, RAID0/1/5/6/10/50) Additional HDD |
| 3 | 3.5inch SATA 2.5inch SATA/SAS PROMISE RAID |
N8103-128 RAID Controller(128MB RAID0/1) Additional HDD |
| 4 | 3.5inch SATA 2.5inch SATA/SAS PROMISE RAID |
N8103-134 RAID Controller(512MB RAID0/1/5/6/10/50) Additional HDD |
| 5 | 3.5inch SATA 2.5inch SATA |
Additional HDD |
| Checklist | Result | Comment | ||
|---|---|---|---|---|
| Conf1,2 | Conf3,4 | Conf5 | ||
| OS installation | A (*1,2) |
A (*1,2) |
A (*1,2) |
Boot from distribution's CD/DVD media. |
| Making partitions | 14 | 14 | 14 | Using the whole drive |
| Hard Drives | A | A | A | Copy and compare data files. |
| Availability of Degraded RAID | A | A | D | RAID 0 is exempt. |
| Rebuild of Degraded RAID | A | A | D | RAID 0 is exempt. |
| I/O access running | 12h | 12h | 12h | I/O access running |
| Reboot | 10 | 10 | 10 | The number of times. |
(*1)NECESSARY
Disable EDAC modules. EDAC module will prevent hardware from collecting IPMI logs which is necessary for hardware support.(*2)NECESSARY
- Add following sentences to /etc/modprobe.conf.
install *_edac /bin/true
install edac_* /bin/true
- Restart the Operation System.
- Check that string "edac" is not shown in the result of lsmod.
Uninstall gnome-disk-utility that incorrectly detects a hard drive failure.
rpm -e gnome-disk-utility
| Basic operation | UP |
| Checklist | Result | Comment |
|---|---|---|
| X Window System | A | 1024x768, thousands colors. |
| Mouse/keyboard | A | Test on X Window System. |
| Built-in LAN ports | A | ssh and ftp |
| Built-in LAN ports Teaming (bonding) | A | Use bonding driver. See the kernel document about bonding. |
| CPU information | A | cat /proc/cpuinfo |
| Memory information | A | cat /proc/meminfo |
| Main memory size | 32 | Main memory size. (GB) |
| Optical disk drive | A | Copy and compare data files. |
| Floppy drive | A | |
| Serial port | A | Configure to login. |
| Hardware Addition | UP |
| Model/Device | Result | |
|---|---|---|
| Hard drive (HDD) | 2.5inch SAS | A |
| 2.5inch SATA | A | |
| 2.5inch SSD | ||
| 3.5inch SATA | A | |
| Backup devices | (*1) | |
| LAN Adapters | (*1) | |
(*1)
See ( HERE ), Option Devices page.
| Backup Devices | UP |
-Hardware configuration
| Connection | Code | Model/Device | Driver |
|---|---|---|---|
| Conn1 | N8103-107 | Additional SCSI Controller (U320) | aic79xx |
| Conn2 | - | USB controller (USB2.0) | - |
| Conn3 | N8103-104A | Additional SAS Controller | mptsas |
| Checklist | Result | Comment | ||
|---|---|---|---|---|
| Conn1 | Conn2 | Conn3 | ||
| Backup, Restore | A | A | A | tar command |
| Reboot | 5 | 5 | 5 | The number of times. |
| go back | UP |