As of Sep 11, 2006
Express5800/140Hf
Distribution Red Hat Enterprise Linux AS4 Update4 EM64T
( KERNEL 2.6.9-42.EL )
Meanings of letters
A ---Function without external drivers
B ---Function with external drivers
C ---Not function
D ---Not Supported
OS Installation / HDDs addition / CPUs addition / Memories addition /
LAN boards addition / Backup Devices /

OS Installation UP

-Hardware configuration

Configuration Code Model/Device qty
Config1
(Onboard RAID)
N8100-1223 Express5800/140Hf
( diskless Model/64bit Intel(R)Xeon(R) MP 3.16GHz 1MB/memory 2GB)
1
N8150-201 Additional 146.5GB HDD(SAS,15krpm) (Onboard RAID,RAID5) 3
N8101-304A Additional CPU (Xeon MP 3.16G/1M) 3
N8102-218 Additional Memory board(DDR2-400,Registered,2GB x 2) 1
Config2
(Onboard RAID)
N8100-1225 Express5800/140Hf
( diskless Model/DualCore Intel(R)Xeon(R) 7041 3GHz 2x2MB/memory 2GB)
1
N8150-200 Additional 73.2GB HDD(SAS,15krpm) (Onboard RAID,RAID5) 3
N8150-200 Additional 73.2GB HDD(SAS,15krpm) (Onboard RAID,RAID0) 6
N8150-200 Additional 73.2GB HDD(SAS,15krpm) (Onboard RAID,RAID1) 2
N8101-341 Additional CPU (Xeon MPD 3G/2x2M) 3
N8154-13 Additional HDD Cage 1
N8102-216 Additional Memory board(DDR2-400,Registered,512MB x 2) 2
N8102-217 Additional Memory board(DDR2-400,Registered,1GB x 2) 2
N8102-218 Additional Memory board(DDR2-400,Registered,2GB x 2) 3

-Evaluation

Checklist Result Comment
Config1 Config2
OS installation A A Boot from Update CD-ROM.
X-Window A A 1024x769, thousands color.
PS/2 Mouse/keyboard A A  
Built-in LAN port A A Telnet, FTP.
Built-in LAN ports Teaming (Bonding) A
(*1)
A
(*1)
Telnet, FTP.
CPU information A A cat /proc/cpuinfo
Memory information A A cat /proc/meminfo
Making partitions 14 14 Using last cylinder of drives.
Hard Drives A A Copy and compare data files.
CD-ROM Drive A A
Floppy Drive A A
Availability of Degraded RAID drive
(Hotplug).
A
(*2)
A
(*2)
Remove one HDD from the running system.
Rebuild of Degraded RAID drive
(Hotplug).
A
(*2)
A
(*2)
Rebuilt of degraded RAID drive automatically.
I/O access running 12h 12h I/O access running
Reboot 10 10 The number of times.
(*1)
Use Bonding driver. (*2)
You can check RAID statuses by HDD LEDs.

HDDs Addition UP

Code Model/Device Result Comment
N8150-199 Additional 36.3GB HDD(SAS,15krpm) A
Copy and compare data files.
N8150-200 Additional 73.2GB HDD(SAS,15krpm)
N8150-201 Additional 146.5GB HDD(SAS,15krpm)

CPUs Addition UP

Code Model/Device qty Result Comment
N8101-304A Additional CPU (Xeon MP 3.16G/1M) 3 A cat /proc/cpuinfo
N8101-341 Additional CPU (Xeon MPD 3G/2x2M) 3 A cat /proc/cpuinfo

Memories Addition UP

Code Model/Device qty Result Comment
N8102-216 Additional Memory board(DDR2-400,Registered,512GBx 2) 8 A cat /proc/meminfo
N8102-217 Additional Memory board(DDR2-400, Registered,1GB x 2) 7 A cat /proc/meminfo
N8102-218 Additional Memory board(DDR2-400,Registered,2GB x 2) 4 A cat /proc/meminfo
N8102-219 Additional Memory board(DDR2-400,Registered,4GB x 2) 8 A cat /proc/meminfo

LAN Boards Addition UP
See ( HERE ), additional LAN board page.

Backup Devices UP
See ( HERE ), Backup Devices page.

-Hardware configuration

Connection Code Model/Device Driver Version
Conn1 N8103-95 Additional SCSI Controller (PCI,U160) aic7xxx 6.2.36
Conn2 N8103-75 Additional SCSI Controller (PCI-X,U320) aic79xx 1.3.11


-Evaluation

Checklist Result Comment
Conn1 Conn2
Backup, Restore A A tar,mt,mtx
Reboot 5 5 The number of times.

go back UP