| Express5800/140Rd-4 | |
| Distribution | Red Hat Enterprise Linux AS3 Update6 EM64T ( KERNEL 2.4.21-37ELsmp ) |
| Meanings of letters |
| A ---Function without external drivers B ---Function with external drivers C ---Not function D ---Not Supported |
| OS Installation / HDDs addition / CPUs addition / Memories addition / LAN boards addition / Backup Devices / |
| OS Installation | UP |
-Hardware configuration
| Configuration | Code | Model/Device | qty |
|---|---|---|---|
| Config1 (Onboard RAID) |
N8100-1035 | Express5800/140Rd-4 (diskless Model/Intel Xeon MP 3.66G/memory 2GB) |
1 |
| N8150-165 | Additional 36.3GB HDD(U320,15krpm)(Onboard RAID,RAID1) | 2 | |
| N8150-163 | Additional 73.2GB HDD(U320,10krpm) (Onboard RAID,RAID5) | 3 | |
| N8101-305 | Additional CPU (Xeon MP 3.66G/1M) | 3 | |
| N8102-216 | Additional Memory board(DDR2-400,Registered,512MB x 2) | 2 | |
| N8102-217 | Additional Memory board(DDR2-400,Registered,1GB x 2) | 4 | |
| N8102-218 | Additional Memory board(DDR2-400,Registered,2GB x 2) | 1 | |
| Config2 (Onboard RAID) |
N8100-1149 | Express5800/140Rd-4 (diskless Model/Intel Xeon MPD 3G/memory 2GB) |
1 |
| N8150-165 | Additional 36.3GB HDD(U320,15krpm)(Onboard RAID,RAID1) | 2 | |
| N8150-163 | Additional 73.2GB HDD(U320,10krpm) (Onboard RAID,RAID5) | 3 | |
| N8101-329 | Additional CPU (Xeon MPD 3G/2x2M) | 1 | |
| N8102-217 | Additional Memory board(DDR2-400,Registered,1GB x 2) | 7 |
| Checklist | Result | Comment | |
|---|---|---|---|
| Config1 | Config2 | ||
| OS installation | A (*1) |
A (*1)(*2) |
Boot from Update6 CD-ROM. |
| X-Window | A | A | |
| PS/2 Mouse/keyboard | A | A | |
| Built-in LAN port | A | A | Telnet, FTP |
| Built-in LAN ports Teaming (Bonding) | A (*3) |
A (*3) |
Telnet, FTP. |
| CPU information | A | A (*2) |
cat /proc/cpuinfo |
| Memory information | A | A | cat /proc/meminfo |
| Making partitions | 14 | 14 | Using last cylinder of drives. |
| Hard Drives(HDD/RAID) | A | A | Copy and compare data files. |
| CD-ROM Drive | A | A | |
| Floppy Drive | A | A | |
| Availability of Degraded RAID drive (Hotplug). |
A (*4) |
A (*4) |
Remove one HDD from the running system. |
| Rebuild of Degraded RAID drive (Hotplug). |
A (*4) |
A (*4) |
Rebuilt of degraded RAID drive automatically. |
| I/O access running | 18h | 17h | I/O access running |
| Reboot | 10 | 10 | More than 5 times |
(*1)
Configuration after installation.(*2)
- If you find a line 'alias scsi_hostadapter megaraid' in /etc/modules.conf, delete it, and if you don't find a line 'alias scsi_hostadapter megaraid2', add it,
- Execute command.
# mkinitrd -f /boot/initrd-2.4.21-37ELsmp.img 2.4.21-37ELsmp- Restart the Operation System.
You must disable Hyper Threading Technology to use more than three CPUs.
"Advanced"
- "Processor "
- "Hyper Thread Technology"
- "Disable"
(*3)
Use Bonding driver.(*4)
- See the kernel document about bonding.
- You must test performance on each environment.
Use Megamonitor to watch RAID status. Get from THIS PAGE .
| HDDs Addition | UP |
| Code | Model/Device | Result | Comment |
|---|---|---|---|
| N8150-165 | Additional 36.3GB HDD(U320,15krpm) | A | Copy and compare data files. |
| N8150-163 | Additional 73.2GB HDD(U320,10krpm) | ||
| N8150-171 | Additional 146.5GB HDD(U320,10krpm) | ||
| N8150-192 | Additional 300GB HDD(U320,10krpm) |
| CPUs Addition | UP |
| Code | Model/Device | qty | Result | Comment |
|---|---|---|---|---|
| N8101-305 | Additional CPU (Xeon MP 3.66G/1M) | 3 | A | cat /proc/cpuinfo |
| N8101-329 | Additional CPU (Xeon MPD 3G/2x2M) | 3 | A | cat /proc/cpuinfo |
| Memories Addition | UP |
| Code | Model/Device | qty | Result | Comment |
|---|---|---|---|---|
| N8102-217 | Additional Memory board(DDR2-400, Registered,1GB x 2) | 7 | A | cat /proc/meminfo |
| N8102-218 | Additional Memory board(DDR2-400,Registered,2GB x 2) | 4 | A | cat /proc/meminfo |
| LAN Boards Addition | UP |
| Backup Devices | UP |
-Hardware configuration
| Connection | Code | Model/Device | Driver | Version |
|---|---|---|---|---|
| Conn1 | N8103-95 | Additional SCSI Controller (PCI,U160) | aic7xxx | 6.2.36 |
| Checklist | Result | Comment |
|---|---|---|
| Conn1 | ||
| I/O access running | A | Check backup and restore operation. |
| Reboot with Backup Devices | A | More than 5 times |
| go back | UP |