As of Nov 30, 2005
Express5800/120Rh-2
Distribution Red Hat Enterprise Linux AS3 Update6 EM64T
( KERNEL 2.4.21-37.ELsmp )
Meanings of letters
A ---Function without external drivers
B ---Function with external drivers
C ---Not function
D ---Not Supported
OS Installation / HDDs addition / CPUs addition / Memories addition /
LAN boards addition / Backup Devices /

OS Installation UP

-Hardware configuration

Configuration Code Model/Device qty
Config1
(SCSI)
N8100-1126 Express5800/120Rh-2
(SCSIdiskless Model/Intel Xeon 3.40G/ 1GB Memory)
1
N8150-193 Additional 146.5GB HDD(U320,15krpm) 1
N8150-172 Additional 73.2GB HDD(U320,15krpm) 1
N8150-192 Additional 300GB HDD(U320,10krpm) 1
Config2
(MegaRAID)
N8100-1125 Express5800/120Rh-2
(SCSIdiskless Model/Intel Xeon 3.20G/ 1GB Memory)
1
N8103-80 Disk Array Controller(1ch,FW:1N39) 1
N8103-79 Battery unit for Disk Array Controller 1
N8150-163 Additional 73.2GB HDD(U320,10krpm) (MegaRAID,RAID5) 3
Config3
(MegaRAID)
N8100-1100 Express5800/120Rh-2
(SCSIdiskless Model/Intel Xeon 3.80G/memory 1GB)
1
N8103-81 Disk Array Controller(2ch,FW:1N39) 1
N8150-163 Additional 73.2GB HDD(U320,10krpm) (MegaRAID,RAID5x2) 6

-Evaluation

Checklist Result Comment
Config1 Config2 Config3
OS installation A
(*1)
A
(*1)
A
(*1)
Boot from Update6 CD-ROM.
X-Window A A A  
PS/2 Mouse/keyboard A A A  
Built-in LAN port A A A Telnet, FTP
Built-in LAN ports Teaming (Bonding) A
(*2)
A
(*2)
A
(*2)
Telnet, FTP.
CPU information A A A cat /proc/cpuinfo
Memory information A A A cat /proc/meminfo
Making partitions 14 14 14 Using last cylinder of drives.
Hard Drives(HDD/RAID) A A A Copy and compare data files.
CD-ROM Drive A A A
Floppy Drive A A A
Availability of Degraded RAID drive - A
(*3)
A
(*3)
Remove one HDD from the running system. (Hotplug).
Rebuild of Degraded RAID drive - A
(*3)
A
(*3)
Rebuilt of degraded RAID drive automatically. (Hotplug).
I/O access running 12h 12h 12h I/O access running
Reboot 5 5 5 More than 5 times
(*1)
You must select VESA instead of RADEON as graphical driver to use X-window system.

(*2)
Use Bonding driver. (*3)
Use Megamonitor to watch RAID status. Get from THIS PAGE .

HDDs Addition UP

Code Model/Device Result Comment
N8150-163 Additional 73.2GB HDD(U320,10krpm) A
Copy and compare data files.
N8150-171 Additional 146.5GB HDD(U320,10krpm)
N8150-192 Additional 300GB HDD(U320,10krpm)
N8150-165 Additional 36.3GB HDD(U320,15krpm) A
Copy and compare data files.
N8150-172 Additional 73.2GB HDD(U320,15krpm)
N8150-193 Additional 146.5GB HDD(U320,15krpm)

CPUs Addition UP

Code Model/Device qty Result Comment
N8101-326 Additional CPU Xeon(3.20G/2M) 1 A cat /proc/cpuinfo
N8101-327 Additional CPU Xeon(3.40G/2M) 1 A
N8101-318 Additional CPU Xeon(3.80G/2M) 1 A

Memories Addition UP

Code Model/Device qty Result Comment
N8102-230 Additional Memory board(DDR2-400, Registered,256MB x2) 4 A cat /proc/meminfo
N8102-231 Additional Memory board(DDR2-400, Registered,512MB x2) 4 A cat /proc/meminfo
N8102-232 Additional Memory board(DDR2-400, Registered,1GB x2) 4 A cat /proc/meminfo
N8102-233 Additional Memory board(DDR2-400, Registered,2GB x2) 4 A cat /proc/meminfo

LAN Boards Addition UP
See ( HERE ), additional LAN board page.

Backup Devices UP
See ( HERE ), Buckup Devices page.

-Hardware configuration

Connection Code Model/Device Driver Version
Conn1 (AIC7902rev.B) Built-in SCSI Controller (U320) aic79xx 1.3.10-RH1
Conn2 N8103-75 Additional SCSI Controller (PCI-X,U320) aic79xx 1.3.10-RH1
Conn3 N8103-95 Additional SCSI Controller (Ultra160) aic7xxx 6.2.36

-Evaluation

Checklist Result Comment
Conn1 Conn2 Conn3
I/O access running A A A Check backup and restore operation.
Reboot with Backup Devices A A A More than 5 times

go back UP