| Express5800/110Ei | |
| Distribution |
Red Hat Enterprise Linux ES 3 Update 3 (KERNEL 2.4.21-20.ELsmp) |
| The following letters given to evaluation results stand for: |
| 'A'---Verified, No drivers required 'B'---Verified, drivers provided 'C'---Not Verified 'D'---Not Supported |
| Installation on Individual HDDs / Installation on RAID drives/ HDDs addition / Memories addition / LAN boards addition / Ethernet Bonding / Backup devices / |
| Installation on Individual HDDs | Top |
-Hardware configuration
| Configuration | Model/Device | Code | qty |
|---|---|---|---|
| HDDs Config.1 (SCSI) |
Express5800/110Ei (Diskless Model/Pentium4 3.80FGHz/Memory -MB) |
N8100-1005 | 1 |
| 512MB Memory | - |
1 | |
| SCSI controller(U320) | N8103-75 | 1 | |
| 73.2GB(10krpm) HDD | N8150-158 | 1 | |
| 109type Keyboard(W) | - | 1 | |
| Mouse (PS2, 2 buttons) | - | 1 |
-Verification
| No. | checklist | result | comment |
|---|---|---|---|
| Config.1 | |||
| 1 | Installation of OS | A | Boot from Update-3 installation CD-ROM.(*1) |
| 2 | HDD | A | cp/mv/diff OK. |
| 3 | FDD | A | |
| 4 | CDROM | A | |
| 5 | on-board LAN | A | Confirmed by telnet and ftp. |
| 6 | Mouse/Keyboard | A | OK. |
| 7 | CPU | A | Hyper-Threading/SMP OK. |
| 8 | Memory | A | /proc/meminfo OK. |
(*1)
- If you see "Warnig", "No Hard drive have found" at the beginning of installation, chose "Yes".
- If you see title "Devices", chose "Add Device".
- At "Select Device Driver to Load", select "Adatptec Aic79xx SCSI Host Bus Adapter driver (Aic79xx)" and "OK"
- If you see title "Devices", chose "Done".
| Installation on RAID drives | Top |
-Hardware Configuration
| RAID Config.1 |
|
|---|
-Verification
| No. | Evaluation | Result | Comment | |
|---|---|---|---|---|
| Cfg.1 | Cfg.2 | |||
| 1 | Operating system installation | A | A | Installation by booting from CD-ROM drive |
| 2 | Create a partition of 4GB or more | A | A | Confirmed by writing and reading data. |
| 3 | Make a file system, mount and unmount it | A | A | |
| 4 | Read/Write at over 2GB region | A | A | |
| 5 | Maximum Number of Partitions | 14 | 14 | |
| 6 | Disk failure/Auto Rebuild | A | A | Auto Rebuild after replacing dead HDD.(*2) |
(*2)
- Get MegaMonitor from HERE, or the newest version from LSI Logic(R).
- Install snd Run this component as follows:
- copy all the files in a temporary directory
- Run "install" script as "./install"
- Run the MegaServ program thru "MegaCtrl -start"
- For other help, type "MegaCtrl -help"
- Logs different events in file "/var/log/megaserv.log" with date & time stamp
| HDDs addition | Top |
| No. | Model/Device | Code | result | verification |
|---|---|---|---|---|
| 1 | SCSI 73.2GB HDD | N8150-158 | A | Connected with SCSI Controller[N8103-75]. cp/mv/diff OK. |
| 2 | SCSI 73.2GB HDD | N8150-163 | A | Connected with SCSI Disk Array
Controller[N8103-80] cp/mv/diff OK. |
| Memories addition | Top |
| No. | Model/Device | Code | qty | result | verification |
|---|---|---|---|---|---|
| 1 | Additional 256MB memory module ( DDR400 ) | N8102-213 | 4 | A | total 1GB OK. |
| 2 | Additional 512MB memory module ( DDR400 ) | N8102-214 | 4 | A | total 2GB OK. |
| 3 | Additional 1G memory module ( DDR400 ) | N8102-215 | 4 | A | total 3.3GB (maximum) OK. |
| LAN boards addition | Top |
| No. | Model/Device | Code | qty | result | verification |
|---|---|---|---|---|---|
| 1 | 1000BASE-T adapter | N8104-103 | 1 | A | Confirmed by telnet and ftp. |
| 2 | 1000BASE-T adapter(2ch) | N8104-113 | 1 | A | |
| 3 | 1000BASE-SX adapter | N8104-112 | 1 | A | |
| 4 | 100BASE-TX adapter(2ch) | N8104-86 | 1 | A | |
| 5 | 100BASE-TX adapter | N8104-111 | 1 | A |
| Ethernet Bonding | Top |
| No. | Model/Device | Code | qty | result | verification | |
|---|---|---|---|---|---|---|
| FT | LB | |||||
| 1 | 100BASE-TX adapter(2ch) | N8104-86 | 1 | A | A | Confirmed fault tolerance function.(*3) It is necessary to test performance of load balancing on your own system. |
| 2 | 1000BASE-T adapter(2ch) | N8104-113 | 1 | A | A | |
(*3)
Confirmed refer to the following kernel source documentation
/usr/src/linux-2.4/Documentation/networking/bonding.txt
| Backup devices | Top |
| No. | Model/Device | Code | qty | result | verification |
|---|---|---|---|---|---|
| 1 | SCSI controller | N8103-65 | 1 | A | Conected with following backup devices.(*4) |
| 2 | built-in AIT(50GB) | N8151-46A | 1 | A | Connected with [N8103-65] Backup/Restore OK. |
| 3 | built-in AIT(100GB) | N8151-41A | 1 | A | |
| 4 | built-in DAT(DDS1/2/3/4)(20GB) | N8151-45 | 1 | A | |
| 5 | built-in DAT(DDS3/4/DAT72)(36GB) | N8151-51 | 1 | A |
(*4)
Install the driver of SCSI controller [N8103-65], as follows.
- Insert Installation CD-ROM #4 into the drive.
- Login as root and run following commands.
# mount /mnt/cdrom # cd /mnt/cdrom/RedHat/RPMS # rpm -ivh kernel-smp-unsupported-2.4.21-20.EL.i686.rpm # cd # eject- Edit /etc/modules.conf and add a following line.
alias scsi_hostadapter a100u2w- Run following commands.
# cd /boot # mkinitrd -f initrd-2.4.21-20.ELsmp.img 2.4.21-20.ELsmp- Reboot the system.
| go back | Top |